🔗 Connect Like a Pro: The Ultimate USB PLC Cable for Next-Level Automation
The EZSync USB PLC Programming Cable is a 3-meter, gold-plated connector cable designed for reliable, corrosion-resistant communication between PCs and Allen Bradley MicroLogix PLCs. Compatible with multiple MicroLogix models and Windows versions, it supports RSLogix 500 and RSLinx via DF1 protocol, ensuring seamless industrial programming and data transfer.
Brand | EZSync |
Connector Type | USB Type A |
Cable Type | USB |
Compatible Devices | PC |
Color | Mini Din and DB9 |
Connector Gender | Male-to-Male |
Shape | Round |
Number of Pins | 8, 9 |
Unit Count | 1 Count |
Item Weight | 2.4 ounces |
Indoor/Outdoor Usage | Outdoor, Indoor |
Manufacturer | Purenitetech |
UPC | 725022296964 |
Package Dimensions | 6.9 x 5.4 x 0.3 inches |
ASIN | B07B9346MQ |
Is Discontinued By Manufacturer | No |
Date First Available | March 6, 2018 |
V**E
Works perfect!
Has little blinky lights on it and it's a very pleasing shade of blue. (Just telling you it works flawless would be boring)
V**6
Works as its supposed to with one minor issue.
Used to connect to a micrologix 1000 plc using the mini din connection, rslinx had no issues connecting and had a stable connection in rslogix to do upload and downloads. Its worth mentioning that the mini din connector is not built the same as the Rockwell version. The Rockwell version has a small alignment notch at the top and a larger one at the bottom, the EZSync cable has three alignment notches (at the 10 o'clock, 2 o'clock and 7 o'clock positions) which causes issues plugging it in easily.
P**R
The EZSync USB PLC Programming Cable for Allen Bradley did ...
The EZSync USB PLC Programming Cable for Allen Bradley did exactly what it was designed to do...communicate!Thanks
D**F
Better than the rest!!
Cable works great and the status lights is a nice bonus to know the PC is communicating to the PLC.
I**
excellent item
works well and the information received was very helpfull
J**Y
Device driver located on website.
This worked perfect for my micrologix 1000.
R**K
Proper PLC Communication Software Set Up is Required
You can use RSLinx (Classic) to properly configure the new connection(s). Communications->Configure Drivers->Add New->Auto-Configure should detect ANY/ALL serial port configurations. Actual detection of a named PLC connection was fully automatic after proper communication was established (may need to run "Configure Driver" again to detect the particular named PLC/connection) . Amazing price compared to the OEM hardware costs of doing the same thing. Tech support responded very quickly via email with response to an unrelated concern.
Trustpilot
3 weeks ago
1 month ago